4 13 wp refrigerant 134a enters the evaporator of a refrigeration syst
Question
4.13 WP Refrigerant 134a
enters the evaporator of a
refrigeration system operating
at steady state at -4°C and
quality of 20% at a velocity of 7
m/s. At the exit, the refrigerant
is a saturated vapor at a
temperature of -4°C. The
evaporator flow channel has
constant diameter. If the mass
flow rate of the entering
refrigerant is 0.1 kg/s,
determine
a. the diameter of the
evaporator flow channel, in
cm.
b. the velocity at the exit, in
m/s.