Please consider a poorly insulated compressor (the system) that was mounted on an external deck aboard the R/V Gould. The compressor Drew kW in electrical power and leaked 2,500 J/sec into the ambient air. The intake air (a diatomic ideal gas) was at 275 °K (the ambient temperature)and 100.0 kPa. The compressor produced high pressure air at 1.0 MPa and600 °K.n--2500W Please write and reduce the Mass Balance for the compressor. Please write and reduce the Energy Balance for the compressor. Please write and reduce the Entropy Balance for the compressor. \text { Please determine } \Delta \bar{h} \text { of the air in } J / \text { mole. } \text { Please determine } \Delta \bar{S} \text { of the air in } J / \circ K \text {-mole. } f. Please find the molar flow rate in mole/sec. Please determine the Ideal Work in J/sec. . Please determine the Ideal Work in J/sec. 1. Please determine the Lost Work in J/sec.