Question

Rig 4 This should be designed so that it can pump water from a source tank round in a loop. Within the loop there must be a pressure indicator, diaphragm

control valve, variable area flow meter (VA) and non-return valve (the non-return valve is to stop water flowing back down through the flow meter). An extra tank and dosing pump should also be included in this system to dose in a chemical (food colouring) just before the control valve (why do you think this might be the case?). Ball valves must also be included so that it is possible to alter the flow path in order to drain the tank and to connect to Rigs 3 and 5. The rig must also be designed so that it is possible for a bypass around the VA (for experimentation) to be added by including termination points. It should also be possible for Rig 4 to receive water back from Rig 5 (use termination points). The following experiments need to be able to be conducted on the individual rigs: a) Determination of the pump curve (pressure versus flowrate) for the centrifugal pump. b) Installation of a bypass line with an orifice plate around the VA, to produce a lower flowrate through the main line. Ratio of flow in the main line in relation to the bypass for each rig are as follows: Rig 1 3:1, Rig 2 4:1, Rig 3 3.5: 1, Rig 4 5:1, Rig 5 4.5:1. When producing any P&ID a lead sheet with a key to the symbols used is vital. For this project the following symbols should be used when drawing your P&ID: Tank PI Pressure Indicator A Hand Operated Valve TI Temperature Indicator Positive Displacement Pump Variable Area Flowmeter Drain S bil Centrifugal Pump Heat Exchanger Control Valve Non-Return Valve Termination Point drain D 401 T401 Water tank H.V 401 XH. Rig 3+ T881 food colour 7402 H.V402 P.wile P401 Woder Pump A5% річої триог N.R valve 402 Rigy 10-10-2023 (Version 4) dose Pump P402 трчоє TP 40s триоза Control Valve 1 TP407 IN.R valve 401 F.I 461 H.V 404 Rig 5 Hand controlled valve 403 трион T401-water tank T402 Colur tank Hv-401- Hand operate valve Hu-402 - Hand operate valve HU-403-17and operate value MU-404 NR.401- non-return valve Hand operafe Value NR.402-non-return valve F.I. 401-Variable area flowmeter Start up (rig 4) (P+11) be virsion 4 All valves are closed fill T401 (water tank) to a minumum of 60%.. Den Hulo2 and HV 404 3 (4 Prime the pump puol (6) Start pyo? (water pump) and adjust can't CV 401 6 fill 1402 to a minumum 60% of chemicals (7) Start P402 (does pump) Shut down Crigu) ( stop puol and P402 become (2) wait until f. I yol and P.1 401 readings quiz Zero (3) close all valves. (4) Drain Tuoi by opening HU 401 wwwwwwwwww www Laus Pi Pressure High €1.90 bar 1.70 ban 1. Yo bar 100 ban 0.80 bar bar 1.75 1.5 1.25 0.75 0.5 0.25 flow meter Q 500 1000 0 L/hr (uopanen & 0% скоркам 500 L/hr 20% 40% B0% 209 950 L/hr 1600 L/hn 2400 W/hr 2500 L/hr 1500 frate aft grening 2000 2500 Je Vo 100 % +/hr