2ohms, and the total rotor and stator reactance per phase in stator terms is 2 2. With rated voltage and frequency applied, the motor slip is0.02. For this condition, find, on a per-phase basis, (a) the stator current (neglect magnetizing current),(b) the developed torque, (c) the rotor power input, (d) the rotor copper loss.Ans. (a) 120 A; (b) 2292 N • m; (c) 144 kW; (d) 2880 W