Design a cylinder rapid mixer for a water treatment plant with a peak flow rate of 45,000 m³/d. The
velocity gradient G in the mixer is to be at least 2,000 s¹ and the detention time is at least 12 s. Determine
the size of the mixing tank, the power input, and the rotational speed of the mixer.
Assume:
H (mix basin height) =D (tank diameter)
D, (impeller diameter): D=0.65
Np=7.1
D=H=1.53 m; Power = 315 W; D-0.574 m; n = 3.84 rps
OD=H=1,43 m; Power = 2315 W; D=0.574 m; n = 1.84 rps
OD=H=2 m; Power = 25000 W; D=1.30 m; n = 0.985 rps
D=H=1.43 m; Power = 2325 W; D=0.274 m; n = 0.84 rps
O D=H=0.43 m; Power = 2315 W; D=1.574 m; n = 1.24 rps
Next page
?