2/23/2024
Assignment 03: Schematic Design - 24W --Design & CAD Project 3 (SEC. 701)
CENTENNIAL 24W --Design & CAD Project 3 (SEC. 701)
COLLEGE
Content Grades Assessments ✓ Communication ✓ Course Tools ▾ Help
Assignment 03: Schematic Design
AR
Д
<
>
://app.readspeaker.com/cgi-bin/rsent?customerid=11151&url=https%3A%2F%2Fe.centennialcollege.ca%2Fcontent%2Fenforced %2F1077099-ARCH 201701_2024W%2FAssignment%252003%2520Schematic%2520Design.html&lang=en_us&readid=d21_read_elen
ASSIGNMENT 03: SCHEMATIC DESIGN
◄ Listen
1024
328
JON
01
5267
02
40
03
10662
DOST
1.02
LOG
S.01
$13
1891
600->
04
05
06
Assignment 03 is worth 10% of your final grade. It is due Sunday of Week 05 by 11:59pm
Project Context
133
fooz
0091
Work on the design and construction drawings for a low-rise commercial building or buildings is an example of the typical work of an architectural
technologist employed in an architectural office. This project will introduce you to the design and construction documentation for a steel frame building with a
range of possibilities for exterior wall construction. During the first part of the project, you will prepare a set of presentation drawings of the commercial
building, for approval by the client. During the second part of the project, you will use these design drawings as the basis for the construction drawings.
Instructions
Your client is a small real estate development company that develops small, low-rise commercial projects in the Greater Toronto Area. The client has
selected a site in the eastern part of Toronto, along Kingston Road. Your project will consist of two, three, or four buildings.
On the ground floor, the overall development will include a number of leasable units for retail stores and personal service shops, and two restaurants. Two of
the buildings will be two storeys and will have leasable office space on the second floor. The office space will be suitable for small businesses or
professionals such as dentists or accountants. Due to the building's height and gross floor area, Part 3 and other parts of the Ontario Building Code will
govern design and construction.
Your task is to design these commercial buildings based upon the area and space requirements provided, recognizing the opportunities and constraints of
the site, the proposed zoning (assuming a successful application for rezoning), the city's Official Plan, and the Toronto Green Standard and Toronto Green
Roof By-Law.
Sustainable Design Requirements
The proposed development must achieve a minimum of Tier 1 under the Toronto Green Standard. It will be necessary to incorporate sustainable design and
construction features in this building in order to reduce energy consumption and operating costs, minimize the building's impact on the environment, provide
a healthy environment for occupants and visitors, and serve as a model for future development in the area.
The following are some of the aspects of sustainable design which this project must address:
•
Resource efficiency: Passive solar design; high performance building envelope
• Site design to maximize permeability
Stormwater runoff rates and stormwater quality
https://e.centennialcollege.ca/d2l/le/content/1077099/viewContent/13599279/View
1/3 2/23/2024
•
Assignment 03: Schematic Design - 24W --Design & CAD Project 3 (SEC. 701)
Green roof, as required by the Toronto Green Roof By-Law
Scenario #1: Two buildings
Building A (approx. 6 retail units + 1 restaurant + office space on 2nd floor)
Building B (approx. 6 retail units + 1 restaurant + office space on 2nd floor)
Scenario #2: Three buildings
Building A (approx. 6 retail units + office space on 2nd floor)
Building B (1 restaurant)
Building C (approx. 6 retail units + 1 restaurant + office space on 2nd floor)
Scenario #3: Four buildings
Building A (approx. 6 retail units + office space on 2nd floor)
Building B (1 restaurant)
Building C (approx. 6 retail units + office space on 2nd floor)
Building D (1 restaurant)
Space Requirements: All areas indicated are approximate.
1st Floor
Leasable Retail/Personal Service Space - Total of 12 units in the project, divided between 2, 3, or 4 buildings
Typical retail unit sizes range from approx. 6m x 18m (based on a column grid of 6m by 6m, or 6m
x 18m overall), 7m x 18m, 7m x 20m, to 7m x 24m. (Some units may be smaller than typical due to
location of Exit Stair #2.) Each unit will include an entrance vestibule, one Universal washroom & a BoH Storage.
Two Restaurants:
Each restaurant: 300 to 400 sq.m.
The restaurants may be attached to buildings containing retail/personal services shops, or they may be in separate buildings, or both.
Each restaurant will include: Entrance vestibule, Dining Area; Kitchen and related functions; Washrooms (Men's, Women's, and Universal Washroom (7.3
sq.m.)); and outdoor patio (this could be also a roof-top patio or both). If a restaurant is in a separate building, it should also have a garbage/recycling
room.
1st Floor
Office Entrance (Related to 2nd Floor office
space), including:
Entrance Vestibule & Lobby
1 Elevator
Stair #1
Stair #2
Garbage/Recycling Room
2nd Floor
1 Elevator
Sq. m.
Sq. m.
Two-Storey
Two-Storey
Bldg. #1
Bldg. #2
20
20
20
20
10
10
10
10
8
8
8
8
15
15
10
110
10
10
16
16
2 Stairs (approx. 8 sq.m. each)
https://e.centennialcollege.ca/d2l/le/content/1077099/viewContent/13599279/View
2/3 2/23/2024
Washrooms (Men's, Women's, and Universal
Washroom (7.3 sq.m.))
Public Corridor
Leasable Office Space
20
Assignment 03: Schematic Design - 24W --Design & CAD Project 3 (SEC. 701)
400
maximum
20
400
maximum
Each proposal must provide the required number of parking spaces for the retail, restaurant, and office components of the development, as per the rezoning
application, as well as the required number of loading spaces and garbage/recycling storage rooms.
Evaluation Rubric
For a total of 30 possible points, Assignment 03 will be graded as follows.
Criteria
Excellent
Thorough
Adequate
Inadequate
Site Plan
9-10 points
7-8 points
5-6 points
0-4 points
(10 points)
First Floor
10-12 points
7-8 points
5-6 points
0-4 points
(10 points)
Second Floor
10-12 points
7-8 points
5-6 points
0-4 points
(10 points)
Total 30 points
Submission
Required Drawings prepared using REVIT and/or AutoCAD and submitted to the Assessment Folder.
• Schematic site plan, showing the footprints of the proposed buildings, building entrances, pedestrian walkways, all parking spaces and aisles, loading spaces, vehicular entrances,
and landscaped areas. Site Plan could be in CAD at this stage but would be much better to insert the base CAD file in REVIT to develop detail lines. The Site Plan should be True
North - Scale 1:500. Draw your Site Plan in REVIT on your Site View using annotation tab: Detail Lines, Filled Region, DIMs, Text, etc.
⚫ Schematic Ground Floor Plan and Second Floor Plan, showing column gridlines, walls, and gross floor area of each portion of the building. Both floor plans will be at 1:100 Scale -
Project North.
.
A few 3D Camera Views to represent your Schematic sustainable and aesthetic considerations.
• Submit: REVIT and a single combined PDF files.
CENTENNIAL
COLLEGE
ARCH-201
Design and Computer Aided Drafting Project 3
Reflect in ePortfolio
Download
Print
Open with docReader
<
>
You have viewed this topic
Last Visited Feb 23, 2024 2:06 PM
https://e.centennialcollege.ca/d2l/le/content/1077099/viewContent/13599279/View
Activity Details
3/3/n This is a 2 part assignment that requires a schematic design and 50% of the design development of the
project. The expert needs to complete the schematic design first in order to begin doing the design
development portion of the project. The expert does not need to complete the design development fully
but rather finish 50% of the design as instructed in the instructions sheet.
This is a 2 part assignment that requires a schematic design and 50% of the design development of the
project. The expert needs to complete the schematic design first in order to begin doing the design
development portion of the project. The expert does not need to complete the design development fully
but rather finish 50% of the design as instructed in the instructions sheet.
The schematic design requires a revit file, 4 sheets (site plan, first floor, 2nd floor plan, 3D)
These tow files compile the design development portion of the assignment
The assignments essentially build off one another, you wont be able to do the design development
portion, without doing the schematic design portion
also the software is Revit
2 design in total if u want to combine the assignments into one, but its not 2 sperate design, its one
design and you build off of it/n PART 1.
The schematic design must be completed in order to get a grade to assess the design dev
elopement of the project therefore it is crucial that multiple files be added. Look at the file names
66
'Assignment 03-Schematic Design” and “Assignment 03-Schematic Design 1" for the
instructions on how to complete Part I of the assignment.
Schematic design requires the following listed below developed in revit:
- Site plan
- first floor plan
- second floor plan
- 3D
I also require 4 sheet views of each of the listed above in revit (Ex, sheet view for the site plan,
first floor plan, second floor plan, and 3D).
Up to this point when you have completed these steps please save the file name as “Schematic
design". I have attached a sample under the file name “Part 1 - Schematic Design- Student
Sample.rte" that shows you exactly what the schematic design format and overall what this
portion of the project should look like. This is a sample, thus please dont copy this the design
must be original. ***IMPORTANT NOTE: This part 1 portion of the project is crucial because
it lays the foundation for part 2 of the project; as per the professors instructions, part 2 will NOT
be assessed or graded if Part I is not complete.***
PART 2.
Using the schematic design, you must not enter the development phase of the project. Part 2 of
this project requires you to prepare design development dragons for the two-story building
schematic design proposal completed in Part I. Look at the file names “Assignment 04- Design
Development” and “Assignment-04- Design Development - Part I 50% od DD".
The design development of the building requires you to prepare on Revit:
-site plan
- Ground floor plan
- Second floor plan
- Building elevations
- Building sections
- 3D views, using revit.
*Please ensure that you include plumbing fixtures on the floor plans, and calculates of the
plumbing fixtures in your site plan statistics* When you have completed part 2 of the assignment, please save the Revit file name as “Design
Development 50%”.
Ive also attached two files called “news.pdf" and "Wall Assembly Hand Sketch
Presentation.pdf”, these are supplementary files that will help you compete the assignment.
By the end of this assignment I required 2 Revit files, one Revit file for part 1 saved under the
name "Schematic Design" and another Revit file for part 2 saved under the name "Design
Development 50%”.