ECE 206
Page 1 of 10
Laboratory Goals
Apply a signal to a resistive circuit and measure both input and output signals
Save a digital copy of the oscilloscope screen to a diskette/file or thumb-drive.
Pre-lab / lab reading
0
Familiarize students with the oscilloscope
Familiarize students with the function generator
00
Lab: Oscilloscope and Signal Generator Use
generator-20-mhz?pm=PL&nid=-536902324.536883183&cc=US&lc=eng
From this page select the Manuals(8) Link on the left under By Type of Content.
It should be the third item in the list.
Agilent 33220A 20 MHz Function/Arbitary Waveform Generator User Guide
http://www.keysight.com/en/pd-127539-pn-33220A/function-arbitrary-waveform-
3000X-Series Oscilloscopes User's Guide, English (or language you want) published by
Agilent Technologies,. (Copies of this reference book are available in the lab, or at the
website)
http://www.keysight.com/en/pdx-x201849-pn-DSOX3052A/oscilloscope-500-
mhz-2-channels?pm=rsc&nid=-32540.1150202&cc=US&lc=eng
Second Link under Manuals on left column under Key Product Information.
for the user guide of the DSOX3052A
For the DSOX3032T user manual, User's Guide for InfinitVision 3000T X-Series
Oscilloscopes, find the second link under Manuals about 1/2 way down the left
side of the page.
http://www.keysight.com/en/pdx-x202174-pn-DSOX3032T/oscilloscope-350-
mhz-2-analog-channels?pm=rsc&nid=-32541.1150351&cc=US&lc=eng
Equipment needed
Lab notebook, pen
□ Agilent/Keysight DSOX3052A Digital Storage Oscilloscope or
Agilent/Keysight DSOX3032T Digital Storage Oscilloscope
Circuit Prototyping breadboard/ELVIS
Agilent/Keysight 33220A Function/Arbitrary Waveform Generator
2 oscilloscope probes
1 BNC/EZ Hook test lead
Parts needed ECE 206
Page 2 of 10
0
☐
Lab safety concerns
0
Resistors (2), 1.5k Ohm, ¼ Watt
Zener diode, 1N4728, 3.3VDC (See TA or Instructor)
0
Lab: Oscilloscope and Signal Generator Use
Make sure before you apply an input signal to a circuit, all connections are
correct, and no shorted wires exist.
1. Exploring the Oscilloscope
Do not short the function generator signal and ground connections together.
Do not touch the circuit wiring while power is applied to it.
Locate the Digital Oscilloscope and obtain two scope probes.
Press the white POWER button to turn on the oscilloscope on the lower left of
the front panel. See 1 in Figure 1: Oscilloscope Controls.
Press the [Help] button. Familiarize yourself with how the controls are changed
using the dials, buttons, or softkeys. The [Help] button is in the lower right of the
manual controls area. See 2 in Figure 1: Oscilloscope Controls.
Press the Default Setup to return the oscilloscope to the default state (Always use
the default before you begin using the oscilloscope!) See 3 in Figure 1:
Oscilloscope Controls
Connect the two probes to their input connectors, marked as 1 or X and 2 or Y on
the Scope. See 4 in Figure 1: Oscilloscope Controls.
Clip the channel 1 (CH 1) probe to the Probe Comp test point at the lower right
below the display. The probe tip goes to the Probe Comp (5). See 5 in Figure 1:
Oscilloscope Controls.
Clip the probe's ground clip to the oscilloscope ground connection to the right of
the Probe Comp test point. The ground clip goes to the horizontal grounding
strip (6). See 6 in Figure 1: Oscilloscope Controls.
Press the Auto-Scale button to acquire the test waveform (i.e., a square wave).
See 7 in Figure 1: Oscilloscope Controls.
Change the vertical scale of the waveform using the CH 1 Volts/Division knob
that is just above the 1, illuminated channel activation button. See 8 in Figure 1:
Oscilloscope Controls. ECE 206
Page 3 of 10
0
0
0
0
Lab: Oscilloscope and Signal Generator Use
Note the Vertical Scale Readout changing in the upper left of the screen and the
displayed waveform changing size as the knob is adjusted. See 1 in Figure 2:
Oscilloscope Screen.
Change the horizontal scale of the waveform using the Sec/Division knob, left
most, top most knob. See 9 in Figure 1: Oscilloscope Controls.
Note the Horizontal Scale Readout changing as the knob is adjusted. See 3 in
Figure 2: Oscilloscope Screen
Press the Auto-Scale button again to resize the waveform
Press the [Meas] button. { See 10 in Figure 1: Oscilloscope Controls.} The
Frequency and peak to peak voltage of channel 1 automatically appears in the
window to the right of the signal window on the display. { See 4 in Figure 2:
Oscilloscope Screen.} Additional measurements for selection can be found using
the lower soft keys under the Screen. The [TYPE] button.{ See 5 in Figure 2:
Oscilloscope Screen.} will produce measurements window on the display, it has a
scroll control knob on the right of the screen for selection {See 6 in Figure 2:
Oscilloscope Screen}
To remove a measurement from the Meas window, use the [Clear Meas], {See 7
in Figure 2: Oscilloscope Screen} Follow the other soft keys that appear.
Record the frequency and peak-to-peak voltage (Vpp) of the square wave in your
lab notebook
Unclip the CH 1 probe and ground clip from the oscilloscope test point and set
them aside
Clip the channel 2 (CH 2) probe and ground clip to the Probe Comp and ground
connections respectively
Repeat the frequency and amplitude measurements for the CH 2 waveform
Clear the screen measurements as before.
Unclip the CH 2 probe and ground clip from the oscilloscope, and set them aside
Always test both probes before taking measurements with them! The test signal
from the oscilloscope should appear square and symmetrical, with no rounding. ECE 206
Page 4 of 10
KEYSIGHT
11.00V/ 2
Time
10
Type DLC Data
Data 4
-10.86ms 000
-8.888ms 0296A950 RMT 5
-6.776ms 0296A950 Data 5
-4.944ms 07F
RMT
Data
-120.Ous 07F
4.192ms OBD
RMT
16.376ms OBD
Data
8.192ms 000
RMT 4
10.28ms 000 Data 4
Data: DE
CAN L-I
CAN
[Search events found 26
Search
S, (CAN)
ON-OFF Switch
Vertical Scale
Readout
Back
Gen out
1 1.00V/ 2
Time
InfiniiVision
KEYSIGHT
Scroll
Lister
CAN_L-H
SCAN
Search events found 26
Search
S, (CAN)
(4)
Gen
Search for
DSO-X 3052A
Mixed Signal Oscilloscope
05 34 F2 14
30 40 00 10 20
DE
65AA
08 50 51 02 53 11 53 0346
280A
19A A6 9E 42
17717 Form
✔All Errors
Remote Frame ID (RTR)
Data Frame ID (-RTR)
Remote or Data Frame 10
Data Frame ID and Data
Error Frame
Overload Frame
Search for
All Errors
******Coddodda
ID
-10.86ms 000
-8.888ms 0296A950 RMT 5
-6.776ms 0296A950 Data
-4.944ms 07F
RMT
Data
-120.0us 07F
4.192ms OBD
RMT
6.376ms OBD
Data
8.192ms 000
RMT 4
10.28ms 000 Data 4
Data:DE
DIGITAL
Scroll
Lister
Type DLC Data
Data 4
Horizontal Scale
Readout
0.0s
Type(measurement)
USB
Connector
11
Search for
200.0%/
CRC Errors
5283
4894
6F1A
6009
4F68
Bits
Search for
All Errors
DIGITAL
Lab: Oscilloscope and Signal Generator Use
200.0/
CRC Errors
15283
D5 34 F2 14
4894
30 40 00 10 20
6F1A
6009
DE
4F68
65AA
08 50 51 02 53 11 53.0346
9A A6 9E 42
Remote Frame ID (RTR)
Data Frame ID (-RTR)
Remote or Data Frame ID
Data Frame ID and Data
Error Frame
All Errors
Overload Frame
0.0s
500 MHz
4 GSa/s
Stop
Bets
CAN
DC
280A
17717 Form
Domo 2
MEGAoom
GA
1.15V
Acquisition
Normal
1.00MSa/s
Probe Compensation
Connections
Channels
Stop
10.0.1
10.0.1
1.00.1
1.00:1
Domo 1
CHANGE
Measurement
Window 4
Figure 1: Oscilloscope Controls
CAN 1 1.15V
Horizontal
Acquisition
Normal
1.00MSa/s
Channels
Trigger
10.0.1
10.0.1
1.00.1
1.00 1
Intensity
~
Y
7
Clear Meas
(clear measurement)
1
Horiz
Search
Trigger
Navigate
Level
- Tools
Utility
Wave
Trigger
Horizontal
~
Scope Probe
Connection Points
Figure 2: Oscilloscope Screen
Force
Trigger
Label
Vertical
2
Mode
Quick
Analyze
1
~
Push to
Horiz
Search
Trigger
Navigate
Utility
Wave
2
Level
- Tools
Horizontal
Scale
10000
-Measure-
Cursors
1MQ2 = 15pF
300 V RMS
CAT I
A
Label
Meas
Acquire
Recall
500 SVRMS
Push to
Zar
Push to
Zero
Trigger
Mode
Coupling
Analyze
Vertical
waveform
V
Help Button
Push to Select
File
Help
Cursors
2
Display
Print
Horizontal Scale
Control
Cursors
Meas
1MQ = 15pF
300 V RMS
CAT I
A
Acquire
500 5 SV RMS
Default
Setup
Waveform
Run
Stop
File
Run Control
Help
Measure
Futh to Select
Cursors
Serial
Digital
Display
Print
Math
Ref
Vertical
Scale
Single
Run
Stop
Default
Setup
Push for Fine
~
Push to Zare
Run Control
Serial
Digital
Math
Ref
6 Selector Knob
Single
-10 Measure
Auto
Scale
~
Push for Fine
Auto
Scale
Default
Setup
12
Save/Recall
Button
Push to Zers ECE 206
Page 5 of 10
2. Exploring the Function Generator
Putting the Function Generator in a known configuration state:
Refer to Figure 3: Function Generator Controls.
Locate the Agilent 33220A 20 MHz Function Generator
Press the white Power button to turn ON the generator. See 2 in Figure 3:
Function Generator Controls.
0
0
Press the [Store/Recall] button to select a stored setup. See 4 in Figure 3:
Function Generator Controls.
Press the [Set to Defaults] soft-key, then the [Yes] soft-key that appears. See 1 in
Figure 3: Function Generator Controls.
Selecting an output waveform:
You can select a waveform by pressing the button with the corresponding symbol
and text button, (sine, square, triangle, or ramp):
O
O
Lab: Oscilloscope and Signal Generator Use
Press the [Square] wave button (notice the square wave symbol appears
on the right side of the display at the Waveform Indicator) See 3 in Figure
3: Function Generator Controls.
You can set the frequency two ways:
Direct entry for 33220A, See 1 and 9 in Figure 3: Function Generator
Controls.
■
I
■
Dial entry for 33220A, See 1, 6, & 8 in Figure 3: Function Generator
Controls.
■
Press the Freq/Period softkey until the desired function is in
reverse video (white background dark letters)
Then press the number buttons for digit entry
Press the (units) multiplier prefix softkey along the bottom of the
display.
Press the Freq/Period softkey until the desired function is in
reverse video(white background dark letters)
Highlight the digit to be changed with the unmarked right left keys
below the adjusting knob on the right side of the front panel.
Turn the Adjusting Knob until the desired number appears on the
Display.