Practical Assignment #5Educate yourselves on human heat and humidity loads by carefully reading Chapter 14.6 in Cengel (9th Ed).
I live near Nike in Beaverton (zip code 97006). First thing in the morning at 7 AM, I took my dog for a walk. Would I
have been able to see my breath on that walk? At the end of the workday at 5 PM, I took my dog for a walk again.
Would I have been able to see my breath on that walk?
Find a good reference/citation for the assumption of the conditions for my exhalation (don't just refer to the same
assumption I used in class without providing justification).
assignment/nLast Class: Wednesday, May 31st
1.) Psychrometric Chart
2.) Dew Point: Tap = Tsat @ Pr
Temperature we're used to
3.1 Dry bulb =
4.) Everything is "per unit mass dry air"
"per unit total mass"
NOT
Adiabatic Saturation Temp (~' Wet Bulb")
Cons of mass: Mr = Mair (W₂_W₁)
Monday, June 5th
Cons of Energy:
1 specific humidity [operator]
Kgair
ma · h₁ + mf hf₂ = mahz
↑
f = saturated liquid
This is the based on which you need to alter the last file/n221310
We can conclude that the dry-bulb temperature, relative humidity, and air motion have
the greatest impact on the human body's comfort. These variables have a substantial impact on
the body's heat transport systems, which include convection, radiation, and evaporation. The
apparent condensation of breath in certain situations is one of the observable phenomena
associated with these thermal exchanges between the body and the environment (Library of
Congress, 2019).
When the air temperature is cold, you can usually see your breath, and there is a big
contrast between that and the temperature of your breath, which is near your body temperature
(about 37°C or 98.6°F). When the warm, moist air exhaled by your body comes into contact with
the cold, outside air, it swiftly cools down. It can't contain as much water vapor as it cools, so the
extra moisture condenses into tiny water droplets, forming a little cloud noticeable as "seeing
your breath" (Library of Congress, 2019).
The temperature was 55°F (about 13°C) with a humidity of 45% at 7 a.m. on June 3,
2023, in Beaverton, Oregon. Breath condensation is most noticeable when the temperature is
around or below 45°F (7°C), a phenomenon most people associate with chilly winter months
(Library of Congress, 2019). However, additional factors like humidity and the individual's body
temperature might impact the exact temperature at which you can see your breath. It would be
feasible but unlikely in this scenario, considering that the temperature was 10°F over the
threshold and the humidity was not particularly high.
At 5 p.m., however, the temperature was 75°F (approximately 24°C) and the humidity
was 40%. Because the temperature difference between exhaled air and the outside environment
is less evident at warmer temperatures, there is a far smaller probability of seeing your breath.
Exhaled air does not cool as quickly, and its water vapor does not condense into visible droplets.
Let's calculate the dew point to check
The temperature at which the air gets saturated (100% relative humidity) and dew forms
is known as the dew point temperature. The dew point may be calculated using the actual air
temperature and relative humidity. The Magnus-Tetens formula (Lawrence, 2005) is used in this
dew point calculator to get reliable answers (with an error of 0.35 °C) for temperatures ranging
from 45 °C to 60 °C
This is the solution and we need to change the equation based on the next file equations/nU= const
Saturation line
23
15°C
To=15°C
Saturation line, 100%
Dry-bulb temperature
$
15°C
FIGURE 14-14
Schematic for a psychrometric chart.
=const.
T=const.
==const.
Tub= 15°C
Specific humidity,
Tap = 15°C
FIGURE 14-15
For saturated air, the dry-bulb, wet-
bulb, and dew-point temperatures are
identical.
chapter
(c) The enthalpy of air per unit mass of dry air is determined from Eq. 14-12:
h₁ = h,+wh,,c,T,+wh
= (1.005 kJ/kg-°C)(25°C) + (0.00653)(2546.5 kJ/kg)
= 41.8 kJ/kg dry air
Discussion The previous property calculations can be performed easily using pro-
grams with built-in psychrometric functions.
14-5. THE PSYCHROMETRIC CHART
The state of the atmospheric air at a specified pressure is completely speci-
fied by two independent intensive properties. The rest of the properties can
be calculated easily from the previous relations. The sizing of a typical air-
conditioning system involves numerous such calculations, which may eventu-
ally get on the nerves of even the most patient engineers. Therefore, there is
clear motivation to computerize calculations or to do these calculations once
and to present the data in the form of easily readable charts. Such charts are
called psychrometric charts, and they are used extensively in air-conditioning
applications. A psychrometric chart for a pressure of 1 atm (101.325 kPa or
14.696 psia) is given in Fig. A-31 in SI units and in Fig. A-31E in English
units. Psychrometric charts at other pressures (for use at considerably higher
elevations than sea level) are also available.
The basic features of the psychrometric chart are illustrated in Fig. 14-14.
The dry-bulb temperatures are shown on the horizontal axis, and the specific
humidity is shown on the vertical axis. (Some charts also show the vapor
pressure on the vertical axis since at a fixed total pressure P there is a one-
to-one correspondence between the specific humidity and the vapor pres-
sure P₁, as can be seen from Eq. 14-8.) On the left end of the chart, there is
a curve (called the saturation line) instead of a straight line. All the saturated
air states are located on this curve. Therefore, it is also the curve of 100 per-
cent relative humidity. Other constant relative-humidity curves have the same
general shape.
Lines of constant wet-bulb temperature have a downhill appearance to the
right. Lines of constant specific volume (in m³/kg dry air) look similar, except
they are steeper. Lines of constant enthalpy (in kJ/kg dry air) lie very nearly
parallel to the lines of constant wet-bulb temperature. Therefore, the constant-
wet-bulb-temperature lines are used as constant-enthalpy lines in some charts.
For saturated air, the dry-bulb, wet-bulb, and dew-point temperatures are
identical (Fig. 14-15). Therefore, the dew-point temperature of atmospheric
air at any point on the chart can be determined by drawing a horizontal line
(a line of @= constant or P, = constant) from the point to the saturated curve.
The temperature value at the intersection point is the dew-point temperature.
The psychrometric chart also serves as a valuable aid in visualizing the
air-conditioning processes. An ordinary heating or cooling process, for
example, appears as a horizontal line on this chart if no humidification or
dehumidification is involved (that is, @= constant). Any deviation from a
horizontal line indicates that moisture is added or removed from the air dur-
ing the process.