Question 1 (4 points) Specified compressive strength of a Portland Cement

Question
Question 1 (4 points)

Specified compressive strength of a Portland Cement Concrete, f'c, is

3,000 psi. Results of the compressive strength in a series of tests are

listed in the Table below:

Strength test no.

Average strength of two cylinders 3,300 3,250 3,150 2,900 3,050

(psi)

3

True

False

Question 2 (4 points)

5

This set of tests concrete meets the ACI acceptance criteria. Please

show your steps

Question 1 options:

1C: 2.02FA : 3.57CA : 0.48W

1C: 2.15FA : 3.57CA : 0.41W

1C: 2.2FA: 3.7CA : 0.48W

1C: 2.20FA : 3CA: 0.48W

Question 3 (6 points)

Mixture design shows a dry mix of 1C:2.0FA:3.5CA:0.50W by weight.

The moisture content and absorption capacity of FA are 0.9 and 1%,

respectively, and those of CA are 2.0 and 1.5%, respectively. Find the

adjusted field wet mix proportion.

Question 2 options:

The amount of water required for non-air-entrained Portland cement

concrete with a specified compressive strength, f'c, of 3500 psi was 300

lbs./yd³. The cement (Type I) added was 560 lbs./yd³.

a) What is the w/c?

b) What is the maximum permissible w/c for trial batch to meet

durability requirement? please indicate the Table you refer

Question image 1