Refrigerant-134a flows through the condenser of a residential heat pump unit. For a give compressor power consumption. Take m=0.018kg/s and Win=1.2KW a. Determine the COP of the heat pump [2.64] b. Calculate the rate of heat absorbed from the outside air [1.96KW]